RAID Storage Sub-System
¡@
¡@
¡@

¡@
| Model |
RAID-Pro 3i
/ 6i New |
RAID-Pro 3s
/ 6s |
| Form Factor |
5 1/4" Half-Height * 6 |
5 1/4" Half-Height * 6 |
| RAID Level |
0, 1, 5 |
0, 1, 3, 5, 0+1 |
| RAID
Processor |
i960RN |
i960RD |
| Cache Memory
|
16MB-64MB |
16MB-64MB |
| No. of Host
Channel |
1 |
1 |
| Host Bus
Interface |
LVD(Ultra2) |
LVD(Ultra2) |
| No. of Disk
Channel |
3 / 6 |
1 |
| Disk Bus
Interface |
EIDE / ATA-3 |
LVD(Ultra2) |
| Data
Transfer Rate |
Up to 80MB/Sec. |
Up to 80MB/Sec. |
| Backplane
Board |
EIDE / ATA-3 |
SCA-II LVD |
| Hot Swap
Disk Trays |
3 (1") / 6 (1") |
3 (1") / 6 (1") |
| Disk Trays
Interface |
EIDE / ATA-3 |
80pin/68pin LVD |
| No. of Disk |
3 / 6 |
3 / 6 |
| Hot Swap
Power Supply |
1 * 250W or 2 * 250W (PS/2) |
1 * 250W or 2 * 250W (PS/2) |
| Cooling Fan |
4(High Speed) |
4(High Speed) |
| RS232 Type
Port |
2 |
2 |
| FAX / Pager
Notification & Password Protection |
Yes |
Yes |
| Audible
Alarm & Failed Disk Indicator |
Yes |
Yes |
| Failed Disk
Auto Rebuild |
Yes |
Yes |
| On-line
Consistency Check & New Disk Auto Spare |
Yes |
Yes |
| Continuous
Rebuild & Host Independent |
Yes |
Yes |
| MTB(hrs) |
>500,000 hrs |
>500,000 hrs |
| Power
Requirement & Environmental |
Power Requirements : AC 110V / 220V
(10%)
Relative Humidity: 10% to 85% Non-condensing Operating Temp: 10oC to 50oC
Non-operating Temp: -40oC to 60oC
Certifications: FCC, CE, UL/CSA, CNS |
Power Requirements : AC 110V / 220V
(10%)
Relative Humidity: 10% to 85% Non-condensing Operating Temp: 10oC to 50oC
Non-operating Temp: -40oC to 60oC
Certifications: FCC, CE, UL/CSA, CNS |
| Physical |
Dimension: 262(H) * 188(W) *
436(D)mm
Weight: 12.5kgs(6 trays) |
Dimension: 380(H) * 190(W) *
350(D)mm Weight:13.5kgs(6 trays) |
¡@
¡@

| Model |
RAID-Pro 6r |
| Form Factor |
19" Rackmount (3U) -5 1/4"
Half-Height * 6 |
| RAID Level |
0, 1, 3, 5, 0+1 |
| RAID
Processor |
i960RD |
| Cache Memory
|
16MB-64MB |
| No. of Host
Channel |
1 |
| Host Bus
Interface |
LVD(Ultra2) |
| No. of Disk
Channel |
6 |
| Disk Bus
Interface |
LVD(Ultra2) |
| Data
Transfer Rate |
Up to 80MB/Sec. |
| Backplane
Board |
SCA-II LVD |
| Hot Swap
Disk Trays |
6 (1") |
| Disk Trays
Interface |
80pin/68pin LVD |
| No. of Disk |
6 |
| Hot Swap
Power Supply |
1 * 250W or 2 * 250W (PS/2) |
| Cooling Fan |
4(High Speed) |
| RS232 Type
Port |
2 |
| FAX / Pager
Notification & Password Protection |
Yes |
| Audible
Alarm & Failed Disk Indicator |
Yes |
| Failed Disk
Auto Rebuild |
Yes |
| On-line
Consistency Check & New Disk Auto Spare |
Yes |
| Continuous
Rebuild & Host Independent |
Yes |
| MTB(hrs) |
>500,000 hrs |
| Power
Requirement & Environmental |
Power Requirements : AC 110V / 220V
(10%)
Relative Humidity: 10% to 85% Non-condensing Operating Temp: 10oC to 50oC
Non-operating Temp: -40oC to 60oC
Certifications: FCC, CE, UL/CSA, CNS |
| Physical |
19" x 3 U EIA standard rack |
¡@
¡@
¡@
¡@
¡@ |