raid_pro1.jpg (40434 bytes)

¡@

Model RAID-Pro 3i / 6i    New RAID-Pro 3s / 6s
Form Factor 5 1/4" Half-Height * 6 5 1/4" Half-Height * 6
RAID Level 0, 1, 5 0, 1, 3, 5, 0+1
RAID Processor i960RN i960RD
Cache Memory 16MB-64MB 16MB-64MB
No. of Host Channel 1 1
Host Bus Interface LVD(Ultra2) LVD(Ultra2)
No. of Disk Channel 3 / 6 1
Disk Bus Interface EIDE / ATA-3 LVD(Ultra2)
Data Transfer Rate Up to 80MB/Sec. Up to 80MB/Sec.
Backplane Board EIDE / ATA-3 SCA-II LVD
Hot Swap Disk Trays 3 (1") / 6 (1") 3 (1") / 6 (1")
Disk Trays Interface EIDE / ATA-3 80pin/68pin LVD
No. of Disk 3 / 6 3 / 6
Hot Swap Power Supply 1 * 250W or 2 * 250W (PS/2) 1 * 250W or 2 * 250W (PS/2)
Cooling Fan 4(High Speed) 4(High Speed)
RS232 Type Port 2 2
FAX / Pager Notification & Password Protection Yes Yes
Audible Alarm & Failed Disk Indicator Yes Yes
Failed Disk Auto Rebuild Yes Yes
On-line Consistency Check & New Disk Auto Spare Yes Yes
Continuous Rebuild & Host Independent Yes Yes
MTB(hrs) >500,000 hrs >500,000 hrs
Power Requirement & Environmental Power Requirements : AC 110V / 220V (10%)
Relative Humidity: 10% to 85% Non-condensing Operating Temp: 10oC to 50oC
Non-operating Temp: -40oC to 60oC
Certifications: FCC, CE, UL/CSA, CNS
Power Requirements : AC 110V / 220V (10%)
Relative Humidity: 10% to 85% Non-condensing Operating Temp: 10oC to 50oC
Non-operating Temp: -40oC to 60oC
Certifications: FCC, CE, UL/CSA, CNS
Physical Dimension: 262(H) * 188(W) * 436(D)mm
Weight: 12.5kgs(6 trays)
Dimension: 380(H) * 190(W) * 350(D)mm Weight:13.5kgs(6 trays)

¡@

¡@

proware_3u1.jpg (88907 bytes)

Model RAID-Pro 6r
Form Factor 19" Rackmount (3U) -5 1/4" Half-Height * 6
RAID Level 0, 1, 3, 5, 0+1
RAID Processor i960RD
Cache Memory 16MB-64MB
No. of Host Channel 1
Host Bus Interface LVD(Ultra2)
No. of Disk Channel 6
Disk Bus Interface LVD(Ultra2)
Data Transfer Rate Up to 80MB/Sec.
Backplane Board SCA-II LVD
Hot Swap Disk Trays 6 (1")
Disk Trays Interface 80pin/68pin LVD
No. of Disk 6
Hot Swap Power Supply 1 * 250W or 2 * 250W (PS/2)
Cooling Fan 4(High Speed)
RS232 Type Port 2
FAX / Pager Notification & Password Protection Yes
Audible Alarm & Failed Disk Indicator Yes
Failed Disk Auto Rebuild Yes
On-line Consistency Check & New Disk Auto Spare Yes
Continuous Rebuild & Host Independent Yes
MTB(hrs) >500,000 hrs
Power Requirement & Environmental Power Requirements : AC 110V / 220V (10%)
Relative Humidity: 10% to 85% Non-condensing Operating Temp: 10oC to 50oC
Non-operating Temp: -40oC to 60oC
Certifications: FCC, CE, UL/CSA, CNS
Physical 19" x 3 U EIA standard rack

¡@

¡@

¡@

¡@

¡@

¡@